讀值準確度(6800+6801) 讀值準確度 (6800+6802) 0.001MW (超載保護 AC200A) 6800+6802 (超載保護 AC2000A) (超載保護 AC3500A) 4 – 300A 4.0V – 500.0 (Phase to Neutral) ± 0.5% ± 5dgts 4.0V – 600.0V (Phase to phase) ± 0.5% ± 5dgts 0.1% 0.1 A 0.1% 0.1mA / 0.1A 0.1% ±10% of reading ±1%
AC(交流)瓦特(50或60Hz,PF(功率因素)0.5到1.CT(比流器比值)=1)
AC(交流)電流( 50 或 60Hz,自動檔位,真均方根值,波峰因素<4,CT=1)
AC(交流)電壓 ( 50 或 60 Hz,自動檔位,真均方根值,波峰因素<4,輸入阻抗10M Ω ,VT(PT)=1CT=1,800V超載保護)
AC(交流)電流的諧波分析(1~99階)6802大電流鉤部
AC(交流)電流的諧波強度(1~99階)6801小電流鉤部,適合CT
AC(交流)電流的諧波分析(1~99階)3007超大電流軟性鉤部
總諧波失真值(THD)
交流電壓峰值(峰值>5V) 或 AC電流 (峰值>20A),VT=1
諧波的波峰因素 (C.F.)(峰值>5V) 或 ACA(峰值範圍>10%),VT=1
在自動模式上的頻率
功率因素(PF)
簡單介紹:
6830+6801(100A)電力品質(zhì)分析儀
詳情介紹:
范圍
解析度
讀值準確度 (6800+3007)
5.0 – 99.9W
0.1W
±1% ± 0.8 w
±1% ± 0.8 w
±1% of Range
1.000 – 9.999 KW
0.001 KW
±1% ± 8 w
±1% ± 8 w
±1% of Range
10.00 – 99.99 KW
0.01 KW
±1% ± 8 0w
±1% ± 8 0w
±1% of Range
100.0 – 999.9 KW
0.1 KW
±1% ± 0.8kw
±1% ± 0.8kw
±1% of Range
1000 – 9999 KW
1 KW
±1% ± 8kw
±1% ± 8kw
±1% of Range
0.000 – 9.999MW
–
±1% ± 8 0kw
–
范圍
解析度
讀值準確度
6800+6801
0.050 – 9.999A
0.00A
±0.5% ± 0.05A
10.00 – 60.00A
0.01A
±0.5% ± 0.5A
60.00 – 99.99A
0.01A
±0.1% ± 0.5A
0.04 – 10.00A
0.01A
–
0.4A – 100.0A
0.1A
±0.5% ± 0.5A
4.0 – 1000.0A
1A
±0.5% ± 5A
6800+3007
0.1A
±1% of Range
300.0 – 999.9A
0.1A
±1% of Range
1000 – 3000A
1A
±1% of Range
范圍
解析度
讀值準確度
范圍
解析度
讀值準確度
0.1V
0.1V
范圍
百分比(%)
電流值(A)
解析度
讀值準確度
解析度
讀值準確度
1 – 20 th
±2%
±2% of reading ± 0.4A
21 – 50 th
4% of reading ±2.0%
±4% of reading ±0.4A
51 – 99 th
6% of reading ±2.0%
±6% of reading ±0.4A
范圍
百分比(%)
電流值(A)
解析度
讀值準確度
解析度
讀值準確度
1 – 10 th
±0.25 of reading ±1%
±0.2% of reading ±7dgts
11 – 20 th
±2% of reading ±1%
±2% of reading ±7dgts
2 1 – 50 th (A范圍)
±5% of reading ±1%
±5% of reading ±7dgts
2 1 – 50 th (mA范圍)
±10% of reading ±1%
±10% of reading ±7dgts
5 1 – 99 th
±35% of reading ±1%
±35% of reading ±7dgts
范圍
百分比(%)
電流值(A)
解析度
讀值準確度
解析度
讀值準確度
1 – 20 th
±2%
0.1A / 1A
±0.2% of Range ±0.4A/40A
21 – 50 th
± 6%
±4% of Range ± 0.4A/40A
51 – 99 th
±10%
±6% of Range ± 0.4A/40A
范圍
解析度
讀值準確度(6801)
讀值準確度(6802)
讀值準確度(3007)
0.0 – 20%
0.1%
±1%
±2%
±2%
20 – 100%
0.1%
±3% of reading ±5%
±6% of reading ±1%
±6% of reading ±1%
100 – 999.9%
0.1%
±10% of reading ±10%
±10% of reading ±1%
范圍
取樣時間
讀值準確度
50Hz
19 μS
±5% ±30digits
60Hz
16 μS
±5% ±30 digits
范圍
解析度
讀值準確度
1.00 – 99.99
0.01
±5% ±30digits
范圍
解析度
讀值準確度
45 – 65Hz
0.1Hz
0.2Hz
范圍
解析度